Following an extensive qualification program, compressor specialist Bitzer has announced approval of the R1234yf and R1234ze(E) HFO refrigerants for its CSH and CSW screw compressors. The two alternatives to R134a have a global warming potential (GWP) of under ten, while the GWP of R134a is around 1,400. With a GWP of about 600 each, the HFO/HFC blends R513A and R450A are also approved for the CSH and CSW series. Unlike the pure HFO refrigerants, they’re nonflammable.

The requirements stipulated by the EU’s F-gas Regulation no. 517/2014 also represent a challenge for manufacturers of refrigeration compressors. In order to meet the phase-down objectives, alternative refrigerants such as hydrofluoroolefins (HFOs) will have to be used in the future.

The volumetric refrigerating capacity and pressure levels of R1234yf are comparable with those of R134a, while the capacity figures and pressure levels of R1234ze(E) are around 20 to 25% lower. Bitzer subjected the R1234yf and R1234ze(E) refrigerants in this group to intensive testing, and the compressors performed well with both in all of the tests and laboratory experiments. The tested compressors achieved nearly identical isentropic efficiency values with R1234yf and R1234ze(E) as with R134a. Due to differences in the thermodynamic properties, the COP measurement results are in some cases slightly lower.

Both of the HFOs are suitable for air conditioning and medium temperature applications in particular, as well as for heat pumps. There’s often a degree of uncertainty regarding flammability. In safety data sheets, R1234ze(E) is listed as nonflammable, though this only applies to transport and storage. When used as a refrigerant, a higher reference temperature of 60°C (140°F) is applied in flammability tests. At this temperature, R1234ze(E) is flammable and therefore assigned to the A2L safety group, just like R1234yf. For this reason, a risk assessment in accordance with the ATEX Directive is required for systems with both refrigerants – with potential consequences in the system design. BITZER compressors for HFO refrigerant fulfill the relevant requirements, making additional evaluation unnecessary.

 

You might also like

Flowserve puts test facility through lab approval program

The Hydraulic Institute has announced that Flowserve Corporation is the latest company to have their pump test laboratory approved through the HI Pump Test Lab Approval Program. The HI program assists

Xylem supplies pump technology for major lock expansion

Xylem has designed a state-of-the-art water pumping solution as part of a complex project to expand the Lanaye Locks in Belgium, a vital connector route between Northern and Southern Europe.

Diaphragm pumps have 4:1 pressure ratio

The Endura-Flo 4D150 and Endura-Flo 4D350 pneumatic paint circulation and supply pumps have a pressure ratio of 4:1. They’re for long-lasting durability and can withstand runaway conditions better than other